Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet

Product Details
Customization: Available
After-sales Service: 1 Year/1000 Hours
Warranty: 1 Year/1000 Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14000
Terms of Payment
LC, T/T
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  • Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
Find Similar Products

Basic Info.

Model NO.
GS-C1000KW
Type
Container Type
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Alternator
Leroy Somer or Equivalent
Model
Open Type/Container Type
Fuel Tank
External Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depends
Engine Model
Qsk35-G5
Certificate
ISO/CE Certificate
Engine
with Cummins Engine
Transport Package
Container
Specification
20ft Container
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Packaging & Delivery

Package Size
6400.00cm * 2400.00cm * 2500.00cm
Package Gross Weight
10600.000kg

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet


Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet




 Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet

Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
  
Diesel Generator Sets Specification CS-C Series:

   

Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
Powered by CUMMINS | 400V, 1500RPM, 50Hz
Genspark Standby Prime Engine Dimension mm Dimension mm Fuel Cons Displacement Cylinder Gov
Model kVA kVA Model Open Type Soundproof Type 75%(L/H) L
GS-C28 28 25 4B3.9-G1 1760*760*1380 2290*1060*1680 5.5 3.9 4 M
GS-C30 30 27.5 4B3.9-G1 1760*760*1380 2290*1060*1680 6 3.9 4 M
GS-C40 44 40 4BT3.9-G1 1760*760*1380 2290*1060*1680 7.9 3.9 4 M
GS-C65 65 60 4BTA3.9-G2 1760*760*1380 2440*1060*1680 10.3 3.9 4 E
GS-C90 90 80 4BTA3.9-G11 1760*760*1380 2600*1060*1680 12 3.9 4 E
GS-C90Q 90 81 QSB3.9-G3 1760*760*1380 2810*1140*1830 13.4 3.9 4 E
GS-C103 102 94 6BT5.9-G1 2300*830*1700 2810*1140*1830 15.6 5.9 6 M
GS-C110  109 100 6BT5.9-G2 2300*830*1700 2810*1140*1830 17.2 5.9 6 E
GS-C110Q 110 100 QSB5.9-G2 2300*830*1700 2810*1140*1830 20.1 5.9 6 E
GS-C125 125 115 6BTA5.9-G2 2300*830*1700 3230*1170*1800 19.3 5.9 6 E
GS-C170 170 156 6BTAA5.9-G12 2390*860*1850 3230*1170*1800 24.6 5.9 6 E
GS-C175 175 160 6CTA8.3-G1 2390*860*1850 3230*1170*1800 29.7 8.3 6 E
GS-C200 200 180 6CTA8.3-G1 2390*860*1850 3230*1170*1800 29.7 8.3 6 E
GS-C200 200 180 6CTA8.3-G2 2390*860*1850 3230*1170*1800 29.7 8.3 6 E
GS-C220 220 200 6CTAA8.3-G2 2450*960*1850 3590*1150*2050 32.2 8.3 6 E
GS-C275D 275 250 6LTAA8.9-G2 2500*960*1850 3590*1150*2050 38.3 8.9 6 E
GS-C275Q 275 250 QSL8.9-G4 2500*1200*1850 3590*1310*2050 46.1 8.9 6 E
GS-C350D 340 310 6LTAA9.5-G1 2500*1160*1850 3890*1460*2150 48 9.5 6 E
GS-C360 350 320 NTA855-G1B 3020*1100*1850 4230*1460*2150 53.5 14 6 E
GS-C375 375 344 NTA855-G2A 3020*1100*1850 4230*1460*2150 53.5 14 6 E
GS-C400 388 350 NTA855-G4 3020*1100*1850  4230*1460*2150   14 6 E
GS-C450 450 NA NTAA855-G7A 3090*1100*1850 4230*1460*2150 71.8 14 6 E
GS-C500 500 450 KTA19-G3 3400*1258*2050 4630*1660*2250 72.8 19 6 E
GS-C550 550 500 KTA19-G3A 3400*1258*2050 4630*1660*2250 80.1 19 6 E
GS-C660 650 575 KTAA19-G6 3650*1638*2050 5030*1860*2550 94.6 19 6 E
GS-C688 688 NA KTAA19-G6A 3650*1638*2050 5030*1860*2550 NA 19 6 E
GS-C700Q 700 635 QSK19-G4 3650*1638*2050 5030*1860*2550 106.8 19 6 E
GS-C825 825 750 KTA38-G2 4550*2100*2320 ISO 20'ft GP 127.3 38 12V E
GS-C880 880 800 KTA38-G2B 4550*2100*2320 ISO 20'ft GP 125.6 38 12V E
GS-C1000 1000 910 KTA38-G2A 4550*2100*2320 ISO 20'ft GP 145.1 38 12V E
GS-C1100 1100 1000 KTA38-G5 4750*2100*2320 ISO 20'ft GP 158.2 38 12V E
GS-C1250 1250 NA KTA38-G9 4750*2100*2320 ISO 20'ft GP NA 38 12V E
GS-C1375Q 1375 1250 QSK38-G5 5000*2200*2500 ISO 20'ft GP 202.3 38 12V E
GS-C1375 1375 1250 KTA50-G3 5000*2200*2500 ISO 20'ft GP 195.9 50 16V E
GS-C1500E 1650 1400 KTA50-G8 5820*2200*2800 NA   50.3 16V E
GS-C1600 1650 1500 KTA50-GS8 5820*2200*2800 ISO 20'ft GP 238.5 50 16V E
GS-C2060Q 2062 1875 QSK60-G3 5820*2200*2800 ISO 40'ft HQ 270.9 60.2 16V E
GS-C2250Q 2250 2050 QSK60-G4 5820*2200*2800 ISO 40'ft HQ 296.2 60.2 16V E
GS-C2500Q 2500 2250 QSK60-G21 5820*2200*2800 ISO 40'ft HQ 363.4 60.2 16V E
 





Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet





Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet
Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet






Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet







Customized Stand by Power Diesel Engine Power Generator 1250 kVA Dg Set Diesel Generator with ATS Cabinet



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 

Welcome your sending inquriy or contact directly!













   

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier