Customization: | Available |
---|---|
After-sales Service: | 1 Year/1000 Hours |
Warranty: | 1 Year/1000 Hours |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Technical Specification:
GF/GFS-C Series Diesel Generator with Cummins Egnine
50Hz Diesel Gneerator Series powered by Cummins |
|||||||||
Generator Set Performance | Engine Specification | Soundproof type | |||||||
Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | |||
50Hz | Prime | Standby | KW | L/H | L*W*H(mm) | KG | |||
KVA | KW | KVA | KW | ||||||
GF/GFS-C250 | 250 | 200 | 275 | 220 | NT855-GA | 231 | 42.7 | 3500*1300*2000 | 3300 |
GF/GFS-C275 | 275 | 220 | 312.5 | 250 | NTA855-G1A | 261 | 60.44 | 3500*1300*2000 | 3500 |
GF/GFS-C313 | 313 | 250 | 344 | 275 | NTA855-G1B | 284 | 61.18 | 3500*1300*2000 | 3500 |
GF/GFS-C344 | 344 | 275 | 375 | 300 | NTA855-G2A | 313 | 64 | 3500*1300*2000 | 3700 |
GF/GFS-C350 | 350 | 280 | 387.5 | 310 | NTA855-G4 | 318 | 65 | 3500*1300*2000 | 3900 |
GF/GFS-C375 | 375 | 300 | 412.5 | 330 | NTAA855-G7 | 343 | 69.9 | 3500*1300*2000 | 3900 |
GF/GFS-C409 | 450 | 360 | NTAA855-G7A | 377 | 76.89 | 3500*1300*2000 | 4150 | ||
GF/GFS-C450 | 450 | 360 | 500 | 400 | KTA19-G3 | 403 | 83.9 | 3800*1400*2100 | 5200 |
GF/GFS-C500 | 500 | 400 | 550 | 440 | KTA19-G3A | 448 | 90 | 4200*1400*2200 | 5400 |
GF/GFS-C525 | 525 | 420 | 631.2 | 505 | KTAA19-G5 | 470 | 97.9 | 4500*1400*2200 | 5900 |
GF/GFS-C575 | 575 | 460 | 650 | 520 | KTAAA19-G6 | 520 | 107.2 | 4500*1400*2200 | 5900 |
GF/GFS-C625 | 687.5 | 550 | KTAA19-G6A | 560 | 116.5 | 4500*1400*2200 | 5900 | ||
GF/GFS-C590 | 650 | 520 | KTA19-G8 | 575 | 116.5 | 4500*1400*2200 | 5900 | ||
GF/GFS-C614 | 675 | 540 | KTA38-GA | 560 | 130 | 5500*2000*2900 | 8000 | ||
GF/GFS-C625 | 625 | 500 | 687.5 | 550 | KTA38-G | 560 | 116.5 | 5500*2000*2900 | 8000 |
GF/GFS-C750 | 750 | 600 | 825 | 660 | KTA38-G2 | 664 | 139.8 | 5500*2000*2900 | 8200 |
GF/GFS-C800 | 800 | 640 | 887.5 | 710 | KTA38-G2B | 711 | 170 | 5500*2000*2900 | 8500 |
GF/GFS-C910 | 910 | 728 | 1001 | 800 | KTA38-G2A | 813 | 170 | 5500*2000*2900 | 8500 |
GF/GFS-C1000 | 1000 | 800 | 1100 | 880 | KTA38-G5 | 880 | 186.4 | 5800*2140*3080 | 9500 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |