50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price

Product Details
Customization: Available
After-sales Service: 1 Year/1000 Hours
Warranty: 1 Year/1000 Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14000
Terms of Payment
LC, T/T
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
  • 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
Find Similar Products

Basic Info.

Model NO.
GF/GFS-C128KW
Type
Basic Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Engine Model
6CTA8.3-G2
Alternator
Leroy Somer or Equivalent
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depends
dB Noise Level
75dB at 7 Meters
Frequency
50Hz/60Hz
Voltage
380V/220V 3 Phase
Transport Package
Wooden Package
Specification
6CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Packaging & Delivery

Package Size
2800.00cm * 1600.00cm * 2000.00cm
Package Gross Weight
1500.000kg

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price


50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price




 50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price

50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price

Diesel Power Generator Set  GF/GFS-C  Series
 
50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price50Hz Generator with Cummins Power 
 
Generator Set Performance Engine Specification Open Genset Soundproof type
Genset Model 50Hz Output Engine Model Power(Kw) Fuel Comsuption(100% Load) Dimension Weight Dimension Weight
50Hz Prime  Standby KW L/H L*W*H (mm) KG L*W*H(mm) KG
KVA KW KVA KW
GF/GFS-C20 20 16 22 17.6 4B3.9-G1/G2 24 5 1700*750*1150 850 1950*830*1200 1250
GF/GFS-C25 25 20 27 22 4B3.9-G1/G2 24 6 1700*750*1150 850 1950*830*1200 1290
GF/GFS-C37 37 30 41 33 4BT3.9-G1/G2 36 8 1820*760*1150 900 2200*950*1200 1350
GF/GFS-C43 42.5 34 47 37 4BT3.9-G1/G2 36 8 1820*760*1150 950 2200*950*1200 1350
GF/GFS-C56 56 45 62 49 4BTA3.9-G2 50 13 1950*830*1150 1070 2400*950*1200 1450
GF/GFS-C73 73 58 80 64 6BT5.9-G1/G2 86-92 23 2150*880*1350 1120 2700*1100*1450 1800
GF/GFS-C85 85 68 94 75 6BT5.9-G1/G2 86-92 23 2150*880*1350 1120 2700*1100*1450 1850
GF/GFS-C100 100 80 110 88 6BT5.9-G1/G2 86-92 23 2150*880*1350 1120 2700*1100*1450 1900
GF/GFS-C113 113 91 125 100 6BTA5.9-G2 110 23 2350*950*1360 1200 2700*1100*1450 2000
GF/GFS-C125 125 100 137 110 6BTA5.9-G2 110 23 2350*950*1360 1235 2700*1100*1450 2100
GF/GFS-C137 138 110 151 121 6BTAA5.9-G2 120 26 2350*950*1360 1400 2800*1150*1560 2150
GF/GFS-C160 160 128 167 141 6CTA8.3-G2 163 34 2470*950*1430 1900 3100*1100*1510 2400
GF/GFS-C187 187 150 206 165 6CTA8.3-G2 163 35.1 2470*950*1430 2000 3100*1100*1510 2450
GF/GFS-C200 200 160 220 176 6CTAA8.3-G2 183 38.7 2600*980*1450 2300 3300*1150*1800 2550
GF/GFS-C225 225 180 248 198 6LTAA8.9-G2 220 38.7 2600*1000*1450 2400 3300*1150*1800 2700
GF/GFS-C250 250 200 275 220 6LTAA8.9-G2 220 41.6 2600*1000*1500 2500 3400*1200*1900 2750



  




  


50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price





50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price
50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price






50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price







50Hz 380V 3 Phase Silent Diesel Generators 160 kVA Generator Price



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 