Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Technical Specification:
Deutz Diesel Engine Generator Set GF/GFS-D Series
50Hz Water-cooled Deutz Series | |||||||||
Generator Set Performance | Engine Specification | Open Genset | Soundproof type | ||||||
Genset Model | 50Hz Output | Engine Model | Dimension | Weight | Dimension | Weight | |||
50Hz | Prime | Standby | L*W*H (mm) | KG | L*W*H(mm) | KG | |||
KVA | KW | KVA | KW | ||||||
GF/GFS-D200 | 200 | 160 | 220 | 176 | BF6M1013-FCG3 | 2500*950*1550 | 1900 | 3200*1150*1600 | 2400 |
GF/GFS-D225 | 225 | 180 | 248 | 198 | BF6M1015-LA GA | 2600*1000*1550 | 2000 | 3300*1150*1850 | 2550 |
GF/GFS-D250 | 275 | 220 | 303 | 242 | BF6M1015C-LA G2A | 2950*1080*1550 | 2650 | 3500*1280*1800 | 3450 |
GF/GFS-D350 | 350 | 280 | 385 | 308 | BF6M1015C-LA G4A | 3150*1150*1550 | 2800 | 3500*1280*1800 | 3600 |
GF/GFS-D375 | 375 | 300 | 413 | 330 | BF6M1015CP-LA G | 3150*1150*1550 | 2950 | 3500*1280*1800 | 3850 |
GF/GFS-D450 | 450 | 360 | 495 | 396 | BF8M1015C-LA G2 | 3500*1350*1750 | 4000 | 3850*1450*1950 | 5100 |
GF/GFS-D500 | 500 | 400 | 550 | 440 | BF8M1015CP-LA G2 | 3500*1350*1750 | 4250 | 3850*1450*1950 | 5500 |
GF/GFS-D550 | 550 | 450 | 600 | 484 | BF8M1015CP-LA G4 | 3500*1350*1750 | 4670 | 3850*1450*1950 | 5950 |
GF/GFS-D600 | 600 | 480 | 660 | 528 | BF8M1015CP-LA G5 | 3500*1350*1750 | 4670 | 3850*1450*1950 | 5950 |
GF/GFS-D625 | 625 | 500 | 688 | 550 | TBD604BL6 | 3500*1350*1750 | 4670 | 3850*1450*1950 | 5950 |
GF/GFS-D750 | 750 | 600 | 825 | 660 | TBD620L6 | 4700*1900*2550 | 7000 | 6000*2100*3000 | 8200 |
GF/GFS-D1500 | 1500 | 1200 | 1650 | 1320 | TBD620V12 | 5900*2010*2550 | 8500 | 7000*2400*3200 | 10800 |
GF/GFS-D2000 | 2000 | 1600 | 2200 | 1760 | TBD620V16 | 5900*2010*2550 | 9200 | 7000*2400*3200 | 11800 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |