Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Product Data Sheet:
Diesel Power Generator Set GF/GFS-P Series with Perkins Power
50Hz Perkins Series Specification | ||||||||
Generator Set Performance | Engine Specification | Open Genset | ||||||
Genset Model | 50Hz Output | Engine Model | Cylinder NO | Dimension | Weight | |||
50Hz | Prime | Standby | L*W*H (mm) | KG | ||||
KVA | KW | KVA | KW | |||||
GS-P8 | 8 | 6.5 | 9 | 7 | 403D-11G | 3 | 1580*810*930 | 359 |
GS-P13 | 13 | 10 | 14 | 11 | 403D-15G | 3 | 1580*810*930 | 370 |
GS-P20 | 20 | 16 | 23 | 18 | 404D-22G | 4 | 1580*810*990 | 460 |
GS-P45 | 45 | 36 | 50 | 40 | 1103A-33TG1 | 3 | 1580*810*1150 | 722 |
GS-P60 | 60 | 48 | 65 | 52 | 1103A-33TG2 | 3 | 1580*810*1150 | 780 |
GS-P65 | 65 | 52 | 73 | 58 | 1104A-44TG1 | 4 | 1580*810*1165 | 800 |
GS-P80 | 80 | 64 | 88 | 70 | 1104A-44TG2 | 4 | 1760*810*1165 | 840 |
GS-P90 | 90 | 72 | 100 | 80 | 1104C-44TAG2 | 4 | 1760*810*1165 | 880 |
GS-P100 | 100 | 80 | 110 | 88 | 1006TG2A | 6 | 2240*960*1315 | 905 |
GS-P150 | 150 | 120 | 165 | 132 | 1006TAG2 | 6 | 2240*960*1315 | 1100 |
GS-P180 | 180 | 144 | 198 | 158 | 1106C-E66TAG4 | 6 | 2345*810*1365 | 1300 |
GS-P250 | 250 | 200 | 275 | 220 | 1306C-E87TAG6 | 6 | 2430*960*1590 | 2270 |
GS-P300 | 300 | 240 | 330 | 264 | 2306A-E13TAG2 | 6 | 3280*1130*1950 | 3100 |
GS-P350 | 350 | 280 | 400 | 320 | 2306A-E13TAG2 | 6 | 3280*1130*1950 | 3500 |
GS-P400 | 400 | 320 | 450 | 360 | 2306A-E13TAG3 | 6 | 3280*1130*1950 | 3800 |
GS-P450 | 450 | 360 | 500 | 400 | 2506A-E15TAG1 | 6 | 3310*1180*1950 | 3950 |
GS-P500 | 500 | 400 | 550 | 440 | 2506A-E15TAG2 | 6 | 3310*1180*1950 | 4000 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |