Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Air Cooled Deutz Generator Set Model in Detail
Technical Specification:
Air Cooled Deutz Engine Generator Set GF/GFS-AD Series
50Hz Air-Cooled Deutz Series |
||||||||||
Generator Set Performance | Engine Specification | Open Genset | ||||||||
Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Cylingder No | Dimension | Weight | |||
50Hz | Prime | Standby | KW | g/kw.h | L*W*H (mm) | KG | ||||
KVA | KW | KVA | KW | |||||||
GF/GFS-AD15 | 15 | 12 | 17 | 13 | F2L912D | 14 | 238 | 2 | 1200*800*1100 | 600 |
GF/GFS-AD25 | 25 | 20 | 27 | 22 | F3L912D | 24 | 232 | 3 | 1400*800*1100 | 700 |
GF/GFS-AD38 | 35 | 28 | 38 | 31 | F4L912D | 32 | 228 | 4 | 1600*800*1100 | 750 |
GF/GFS-AD43 | 42.5 | 34 | 47 | 36 | F4L912TD | 41 | 228 | 6 | 1600*800*1100 | 780 |
GF/GFS-AD50 | 50 | 40 | 55 | 44 | BF4L913D | 47 | 229 | 6 | 1600*800*1100 | 800 |
GF/GFS-AD50 | 50 | 40 | 55 | 44 | F6L912D | 48 | 228 | 6 | 1800*800*1100 | 880 |
GF/GFS-AD56 | 56 | 45 | 59 | 48 | F6L913D | 51 | 228 | 6 | 1800*800*1100 | 950 |
GF/GFS-AD63 | 62.5 | 50 | 69 | 55 | F6L912TD | 61 | 228 | 6 | 1800*800*1100 | 980 |
GF/GFS-AD75 | 75 | 60 | 82.5 | 66 | BF6L913D | 74 | 228 | 6 | 1900*800*1150 | 1050 |
GF/GFS-AD94 | 94 | 75 | 102 | 82 | BF6L913CD | 84 | 221 | 6 | 1900*800*1150 | 1150 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |