400V 220V Double Voltage Diesel Power 500kw Silent Generator

Product Details
Customization: Available
After-sales Service: 1 Year/1000 Hours
Warranty: 1 Year/1000 Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14000
Terms of Payment
LC, T/T
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
  • 400V 220V Double Voltage Diesel Power 500kw Silent Generator
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • After Sales Service
Overview

Basic Info.

Model NO.
GF/GFS-WC500KW
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Engine
Weichai Power
Alternator
Leroy Somer or Equivalent
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Voltage
Double Voltage
Frequency
60Hz
Transport Package
Wooden Package
Specification
11CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Packaging & Delivery

Package Size
5800.00cm * 2350.00cm * 2500.00cm
Package Gross Weight
7500.000kg

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.


With more than 20 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.


400V 220V Double Voltage Diesel Power 500kw Silent Generator

 
Product Description

400V 220V Double Voltage Diesel Power 500kw Silent Generator

400V 220V Double Voltage Diesel Power 500kw Silent Generator

400V 220V Double Voltage Diesel Power 500kw Silent Generator



Technical Specification:

GF/GFS-WC Series Weichai diesel generator

400V 220V Double Voltage Diesel Power 500kw Silent Generator


  

 

400V 220V Double Voltage Diesel Power 500kw Silent Generator
400V 220V Double Voltage Diesel Power 500kw Silent Generator

 


400V 220V Double Voltage Diesel Power 500kw Silent Generator



 
Detailed Photos

400V 220V Double Voltage Diesel Power 500kw Silent Generator

400V 220V Double Voltage Diesel Power 500kw Silent Generator


 

400V 220V Double Voltage Diesel Power 500kw Silent Generator




400V 220V Double Voltage Diesel Power 500kw Silent Generator






400V 220V Double Voltage Diesel Power 500kw Silent Generator
400V 220V Double Voltage Diesel Power 500kw Silent Generator
400V 220V Double Voltage Diesel Power 500kw Silent Generator

 
After Sales Service

-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------

Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 

Welcome your sending inquiry and directly contact!  










 