![]() 60Hz Diesel Generator with Cummins engine |
|||||||||
Generator Set Performance | Engine Specification | Soundproof type | |||||||
Genset Model | 60Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | |||
60Hz | Prime | Standby | KW | L/H | L*W*H(mm) | KG | |||
KVA | KW | KVA | KW | ||||||
G/GS-C313 | 312.5 | 250 | 344 | 275 | NTA855-G1 | 287 | 61.18 | 3500*1300*2000 | 3500 |
G/GS-C313 | 313 | 250 | 350 | 280 | NTA855-G1B | 313 | 65 | 3500*1300*2000 | 3700 |
G/GS-C394 | 394 | 315 | 433 | 347 | NTA855-G3 | 358 | 76.9 | 3500*1300*2000 | 3900 |
G/GS-C438 | 438 | 350 | 481 | 385 | KTA19-G2 | 392 | 85.4 | 4200*1400*2100 | 5200 |
G/GS-C513 | 513 | 410 | 564 | 451 | KTA19-G3 | 463 | 100 | 4200*1400*2100 | 5200 |
G/GS-C563 | 563 | 450 | 625 | 500 | KTA19-G3A | 507 | 105 | 4500*1650*2250 | 5500 |
G/GS-C563 | 563 | 450 | 619 | 495 | KTA19-G4 | 507 | 109 | 4500*1650*2250 | 5500 |
G/GS-C587 | 587.5 | 470 | 687.5 | 550 | KTAA19-G5 | 533 | 117 | 4500*1650*2250 | 5900 |
G/GS-C687 | 687 | 550 | 756 | 605 | KTAA19-G6A | 600 | 128 | 4500*1650*2250 | 5900 |
G/GS-C775 | 775 | 620 | 853 | 682 | KTA38-G | 697 | 144 | 5500*2000*2900 | 8000 |
G/GS-C750 | 906 | 725 | 997 | 798 | KTA38-G2 | 809 | 169 | 5500*2000*2900 | 8200 |
G/GS-C1000 | 1000 | 800 | 1100 | 880 | KTA38-G2A | 915 | 186.4 | 5500*2000*2900 | 8500 |
G/GS-C1250 | 1125 | 900 | 1238 | 990 | KTA38-G4 | 1007 | 210 | 5800*2140*3080 | 9500 |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |