Customization: | Available |
---|---|
After-sales Service: | 1 Year/1000 Hours |
Warranty: | 1 Year/1000 Hours |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Technical Specification:
GF/GFS-C Series Diesel Generator with Cummins Egnine
50Hz Generator with Cummins Power | |||||||||||
Generator Set Performance | Engine Specification | Open Genset | Soundproof type | ||||||||
Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | Dimension | Weight | |||
50Hz | Prime | Standby | KW | L/H | L*W*H (mm) | KG | L*W*H(mm) | KG | |||
KVA | KW | KVA | KW | ||||||||
GF/GFS-C20 | 20 | 16 | 22 | 17.6 | 4B3.9-G1/G2 | 24 | 5 | 1700*750*1150 | 850 | 1950*830*1200 | 1250 |
GF/GFS-C25 | 25 | 20 | 27 | 22 | 4B3.9-G1/G2 | 24 | 6 | 1700*750*1150 | 850 | 1950*830*1200 | 1290 |
GF/GFS-C37 | 37 | 30 | 41 | 33 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 900 | 2200*950*1200 | 1350 |
GF/GFS-C43 | 42.5 | 34 | 47 | 37 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 950 | 2200*950*1200 | 1350 |
GF/GFS-C56 | 56 | 45 | 62 | 49 | 4BTA3.9-G2 | 50 | 13 | 1950*830*1150 | 1070 | 2400*950*1200 | 1450 |
GF/GFS-C73 | 73 | 58 | 80 | 64 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 | 2700*1100*1450 | 1800 |
GF/GFS-C85 | 85 | 68 | 94 | 75 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 | 2700*1100*1450 | 1850 |
GF/GFS-C100 | 100 | 80 | 110 | 88 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 | 2700*1100*1450 | 1900 |
GF/GFS-C113 | 113 | 91 | 125 | 100 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1200 | 2700*1100*1450 | 2000 |
GF/GFS-C125 | 125 | 100 | 137 | 110 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1235 | 2700*1100*1450 | 2100 |
GF/GFS-C137 | 138 | 110 | 151 | 121 | 6BTAA5.9-G2 | 120 | 26 | 2350*950*1360 | 1400 | 2800*1150*1560 | 2150 |
GF/GFS-C160 | 160 | 128 | 167 | 141 | 6CTA8.3-G2 | 163 | 34 | 2470*950*1430 | 1900 | 3100*1100*1510 | 2400 |
GF/GFS-C187 | 187 | 150 | 206 | 165 | 6CTA8.3-G2 | 163 | 35.1 | 2470*950*1430 | 2000 | 3100*1100*1510 | 2450 |
GF/GFS-C200 | 200 | 160 | 220 | 176 | 6CTAA8.3-G2 | 183 | 38.7 | 2600*980*1450 | 2300 | 3300*1150*1800 | 2550 |
GF/GFS-C225 | 225 | 180 | 248 | 198 | 6LTAA8.9-G2 | 220 | 38.7 | 2600*1000*1450 | 2400 | 3300*1150*1800 | 2700 |
GF/GFS-C250 | 250 | 200 | 275 | 220 | 6LTAA8.9-G2 | 220 | 41.6 | 2600*1000*1500 | 2500 | 3400*1200*1900 | 2750 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |