MTU Diesel Generator Set/ 400V, 1500RPM, 50Hz ![]() |
|||||||||
Model | Standby | Prime | Engine | Dimension mm | Dimension mm | Fuel Cons | Displacement | Cylinder | Gov |
kVA | kVA | Model | Open Type | Soundproof Type | 75%(L/H) | L | |||
GF/GFS-M825 | 825 | 750 | 12V2000G65 | 4500*2100*2080 | 5800*1800*2550 | 123 | 23.88 | 12V | E |
GF/GFS-M880 | 880 | 800 | 12V2000G65 | 4500*2100*2080 | 5800*1800*2550 | 129 | 23.88 | 12V | E |
GF/GFS-M1250 | 1250 | 1135 | 18V2000G65 | 4600*2100*2300 | ISO 20'ft GP | 178 | 35.82 | 18V | E |
GF/GFS-M1800 | 1800 | 1640 | 12V4000G23 | 3960*1835*2260 | ISO 40'ft HQ | 242 | 57.2 | 12V | E |
GF/GFS-M2000 | 2000 | 1850 | 12V4000G63 | 3980*1845*2270 | ISO 40'ft HQ | 271 | 57.2 | 12V | E |
GF/GFS-M2250 | 2250 | 2050 | 16V4000G23 | 4790*1845*2270 | ISO 40'ft HQ | 302 | 76.3 | 16V | E |
GF/GFS-M2500 | 2500 | 2275 | 16V4000G63 | 5450*1845*2560 | ISO 40'ft HQ | 330 | 76.3 | 16V | E |
GF/GFS-M2750 | 2750 | 2500 | 20V4000G23 | 5650*1900*2650 | ISO 40'ft HQ | 379 | 95.4 | 20V | E |
GF/GFS-M3000 | 3000 | 2750 | 20V4000G63 | 5700*1950*2700 | ISO 40'ft HQ | 415 | 95.4 | 20V | E |
GF/GFS-M3000 | 3000 | 2750 | 20V4000G24F or 20V4000G74F | 5700*1950*2700 | ISO 40'ft HQ | 415 | 95.4 | 20V | E |
GF/GFS-M3250 | 3250 | 3000 | 20V4000G63L | 5750*1980*2750 | ISO 40'ft HQ | 450 | 95.4 | 20V | E |
GF/GFS-M3600 | 3575 | 3250 | 20V4000G44F or 20V4000G94F | 6250*2320*2500 | ISO 40'ft HQ | € 472 | 95.4 | 20V | E |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |