50Hz Diesel Generator Series powered by Cummins |
||||||||||
Generator Set Performance | Engine Specification | Open Genset | Soundproof type | |||||||
Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | Dimension | |||
50Hz | Prime | Standby | KW | L/H | L*W*H (mm) | KG | L*W*H(mm) | |||
KVA | KW | KVA | KW | |||||||
G/GS-C350 | 350 | 280 | 387.5 | 310 | NTA855-G4 | 318 | 65 | 3000*1100*1800 | 3050 | 3500*1300*2000 |
G/GS-C375 | 375 | 300 | 412.5 | 330 | NTAA855-G7 | 343 | 69.9 | 3000*1100*1800 | 3100 | 3500*1300*2000 |
G/GS-C409 | 450 | 360 | NTAA855-G7A | 377 | 76.89 | 3000*1100*1800 | 3300 | 3500*1300*2000 | ||
G/GS-C450 | 450 | 360 | 500 | 400 | KTA19-G3 | 403 | 83.9 | 3450*1300*1800 | 4000 | 3800*1400*2100 |
G/GS-C500 | 500 | 400 | 550 | 440 | KTA19-G3A | 448 | 90 | 3450*1300*2000 | 4200 | 4200*1400*2200 |
G/GS-C500 | 500 | 400 | 550 | 440 | KTA19-G4 | 448 | 93.2 | 3850*1300*2000 | 4300 | 4200*1400*2200 |
G/GS-C525 | 525 | 420 | 631.2 | 505 | KTAA19-G5 | 470 | 97.9 | 3850*1300*2000 | 4600 | 4500*1400*2200 |
G/GS-C625 | 687.5 | 550 | KTAA19-G7 | 560 | 116.5 | 3850*1300*2000 | 4600 | 4500*1400*2200 | ||
G/GS-C590 | 650 | 520 | KTA19-G8 | 575 | 116.5 | 3850*1300*2000 | 4600 | 4500*1400*2200 | ||
G/GS-C614 | 675 | 540 | KTA38-GA | 560 | 130 | 4500*1800*2450 | 6950 | 5500*2000*2900 | ||
G/GS-C625 | 625 | 500 | 687.5 | 550 | KTA38-G | 560 | 116.5 | 4500*1800*2450 | 6950 | ISO20GP |
G/GS-C750 | 750 | 600 | 825 | 660 | KTA38-G2 | 664 | 139.8 | 4500*1800*2450 | 7050 | ISO20GP |
G/GS-C800 | 800 | 640 | 887.5 | 710 | KTA38-G2B | 711 | 170 | 4500*1800*2450 | 7200 | ISO20GP |
G/GS-C910 | 910 | 728 | 1001 | 800 | KTA38-G2A | 813 | 170 | 4500*1800*2450 | 7200 | ISO20GP |
G/GS-C1000 | 1000 | 800 | 1100 | 880 | KTA38-G5 | 880 | 186.4 | 4800*1950*2400 | 7900 | ISO20GP |
G/GS-C1136 | 1250 | 1000 | KTA38-G9 | 1000 | 196 | 5800*2010*2500 | 8500 | ISO20GP | ||
G/GS-C1200 | 1200 | 960 | 1320 | 1056 | QSK38-G5 | 1063 | 220 | 5800*2010*2500 | 9000 | ISO20GP |
G/GS-C1250 | 1250 | 1000 | 1375 | 1100 | KTA38-G3 | 1097 | 233 | 5800*2010*2500 | 9000 | ISO40GP |
G/GS-C1375 | 1375 | 1100 | 1513 | 1210 | KTA50-G8 | 1200 | 256.3 | 5800*2010*2500 | 9000 | ISO40GP |
G/GS-C1450 | 1450 | 1160 | 1625 | 1300 | KTA50-GS8 | 1287 | 273 | 5800*2010*2500 | 9000 | ISO40GP |
G/GS-C1650 | 1650 | 1320 | 1815 | 1452 | QSK50-G7 | 5800*2250*2660 | 12700 | ISO40GP | ||
G/GS-C2000 | 2000 | 1600 | 2200 | 1760 | QSK60-G4 | 2800*2250*2660 | 14500 | ISO40GP | ||
G/GS-C2250 | 2250 | 1800 | 2500 | 2000 | QSK60-G13 | 6150*2580*2700 | 14500 | ISO40GP |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |