60Hz Weifang Series | ||||||||||
Generator Set Performance | Engine Specification | Soundproof type | ||||||||
Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Cylingder No | Dimension | Weight | |||
60Hz | Prime | Standby | KW | g/kw.h | L*W*H(mm) | KG | ||||
KVA | KW | KVA | KW | |||||||
G/GS-W12 | 12.5 | 10 | 13.8 | 11 | SL2100ABD | 17.3 | ≈257 | 2 | 1700*900*1150 | 800 |
G/GS-W15 | 15 | 12 | 16.5 | 13 | SL2100ABD | 17.3 | ≈257 | 2 | 1700*900*1150 | 850 |
G/GS-W20 | 20 | 16 | 22 | 17.6 | 495D8 | 33 | ≈256 | 4 | 2000*900*1200 | 900 |
G/GS-W25 | 25 | 20 | 27.5 | 22 | 495D8 | 33 | ≈256 | 4 | 2000*900*1200 | 950 |
G/GS-W30 | 30 | 24 | 33 | 26.4 | K4100D | 34 | ≈256 | 4 | 2000*900*1200 | 990 |
G/GS-W35 | 35 | 28 | 38.5 | 31 | K4100D | 34 | ≈256 | 4 | 2250*1000*1300 | 1050 |
G/GS-W37.5 | 37.5 | 30 | 41 | 33 | 4100ZD | 40 | ≈256 | 4 | 2250*1000*1300 | 1100 |
G/GS-W45 | 45 | 36 | 50 | 40 | 4100ZD | 45 | ≈256 | 4 | 2250*1000*1300 | 1170 |
G/GS-W50 | 50 | 40 | 55 | 44 | R4110D40 | 54 | ≈256 | 4 | 2250*1000*1300 | 1200 |
G/GS-W63 | 63 | 50 | 69 | 55 | R4105ZD | 60 | ≈231 | 4 | 2250*1000*1300 | 1300 |
G/GS-W73 | 73 | 58 | 80 | 80 | R6105D | 68 | ≈231 | 4 | 2800*1150*1610 | 1350 |
G/GS-W94 | 94 | 75 | 103 | 83 | R6105ZD | 88 | ≈231 | 6 | 2800*1150*1610 | 1450 |
G/GS-W113 | 113 | 90 | 124 | 99 | R6105ZLD | 113 | ≈231 | 6 | 2800*1150*1610 | 1500 |
G/GS-W125 | 125 | 100 | 138 | 110 | R6105AZLD | 120 | ≈218 | 6 | 2800*1150*1610 | 1650 |
G/GS-W150 | 150 | 120 | 165 | 132 | R6105IZLD | 136 | ≈218 | 6 | 2800*1150*1610 | 1700 |
G/GS-W187 | 187 | 150 | 206 | 165 | R6113ZLD | 165 | ≈218 | 6 | 2800*1150*1610 | 1800 |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |