Customization: | Available |
---|---|
After-sales Service: | 1 Year/1000 Hours |
Warranty: | 1 Year/1000 Hours |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
Technical Specification:
YangDong Diesel Power Generator Set GF/GFS-Y Series
60Hz YangDong Series | |||||||||||
Generator Set Performance | Engine Specification | Open Genset | Soundproof type | ||||||||
Genset Model | 60Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | Dimension | Weight | |||
60Hz | Prime | Standby | KW | g/kw.h | L*W*H (mm) | KG | L*W*H(mm) | KG | |||
KVA | KW | KVA | KW | ||||||||
GF/GFS-Y10 | 10 | 8 | 11 | 8.8 | YD380 | 10 | 245 | 1520*670*1110 | 500 | 1700*900*1130 | 640 |
GF/GFS-Y12 | 12.5 | 10 | 13.8 | 11 | YD480D | 14 | 240 | 1520*670*1110 | 520 | 1700*900*1130 | 690 |
GF/FGS-Y15 | 15 | 12 | 16.5 | 13.2 | YD4KD | 15 | 240 | 1520*670*1110 | 540 | 1800*900*1130 | 740 |
GF/GFS-Y17 | 17.5 | 14 | 19.3 | 15.4 | YND485 | 17 | 230 | 1540*670*1110 | 560 | 1800*900*1130 | 760 |
GF/GFS-Y20 | 20 | 16 | 22 | 17.6 | YSD490D | 21 | 225 | 1540*750*1130 | 586 | 2060*910*1150 | 780 |
GF/GFS-Y25 | 25 | 20 | 27.5 | 22 | Y490H | 24 | 225 | 1660*750*1130 | 610 | 2060*910*1150 | 840 |
GF/GFS-Y30 | 30 | 24 | 33 | 26.4 | Y4100D | 31.5 | 223 | 1700*750*1130 | 700 | 2060*910*1150 | 880 |
GF/GFS-Y35 | 35 | 28 | 37 | 30 | Y4102D | 33 | 220 | 1700*750*1130 | 720 | 2060*910*1150 | 906 |
GF/GFS-Y37 | 37.5 | 30 | 41 | 33 | Y4102ZD | 40 | 215 | 1740*750*1130 | 793 | 2200*100*1200 | 1100 |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |