Generator with DOOSAN Egnine 50Hz![]() |
|||||||||||
Generator Set Performance | Engine Specification | Open Genset | Soundproof type | ||||||||
Genset Model | 50Hz Output | Engine Model | Cyl | Fuel Comsuption(100% Load) | Dimension | Weight | Dimension | Weight | |||
50Hz | Prime | Standby | L/H | L*W*H (mm) | KG | L*W*H(mm) | KG | ||||
KVA | KW | KVA | KW | ||||||||
GS-DS120KW | 150 | 120 | 165 | 132 | DP086TA | 6L | 35.4 | 2470*950*1430 | 1900 | 3100*1100*1510 | 2400 |
GS-DS180KW | 225 | 180 | 250 | 200 | DP086LA | 6L | 43.1 | 2470*950*1430 | 2000 | 3100*1100*1510 | 2450 |
GS-DS216KW | 270 | 216 | 300 | 240 | P126TI | 6L | 53.4 | 2600*980*1450 | 2300 | 3300*1150*1800 | 2550 |
GS-DS240KW | 300 | 240 | 330 | 264 | P126TI-II | 8V | 63.1 | 3050*1430*1950 | 3124 | 4350*1700*2260 | 4024 |
GS-DS280KW | 350 | 280 | 385 | 308 | P158LE-1 | 8V | 78.1 | 3050*1430*1950 | 3124 | 4350*1700*2260 | 4024 |
GS-DS360KW | 450 | 360 | 500 | 400 | DP158LC | 8V | 97.4 | 3050*1430*1950 | 3370 | 4350*1700*2260 | 4279 |
GS-DS420KW | 525 | 420 | 575 | 460 | DP158LD | 8V | 114.4 | 3050*1430*1950 | 3443 | 4350*1700*2260 | 4343 |
GS-DS440KW | 550 | 440 | 605 | 484 | DP180LA | 10V | 120.1 | 3050*1430*1950 | 3443 | 4350*1700*2260 | 4343 |
GS-DS500KW | 625 | 500 | 688 | 550 | DP180LB | 10V | 136.4 | 3050*1430*1950 | 3883 | 4350*1700*2260 | 4532 |
GS-DS536KW | 670 | 536 | 738 | 590 | DP222LB | 12V | 147.1 | 3480*1430*1950 | 4542 | 4950*1800*2515 | 5248 |
GS-DS590KW | 738 | 590 | 813 | 650 | DP222LC | 12V | 161 | 3480*1430*1950 | 4542 | 4950*1800*2515 | 5248 |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |