• 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
  • 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
  • 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
  • 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
  • 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
  • 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator

60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator

After-sales Service: 1 Year/1000 Hours
Warranty: 1 Year/1000 Hours
Type: Micro-Computer Control Automatic Diesel Generator
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator pictures & photos
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
US $10,400-12,400 / set
Min. Order: 1 set
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
GF/GFS-D128KW
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Engine
Deutz Engine
Engine Model
Tbd226b-6D5
Alternator
Leroy Somer or Equivalent
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depend on Choice
Alternative Function
Remote Control
Frequency
50Hz
Voltage
50Hz 400V/230V
Phase
3 Phase 4 Wires
Transport Package
Wooden Package
Specification
10CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Packaging & Delivery

Package Size
3000.00cm * 2000.00cm * 1800.00cm
Package Gross Weight
3400.000kg

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator


60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator




 60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator

60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator


Deutz Diesel Engine Generator Set  GF/GFS-D Series
 
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator50Hz Water-cooled Deutz Series
 
Generator Set Performance Engine Specification Soundproof type
Genset Model 50Hz Output Engine Model Power(Kw) Fuel Comsuption(100% Load) Cylingder No Dimension Weight
50Hz Prime  Standby KW g/kw.h   L*W*H(mm) KG
KVA KW KVA KW
GF/GFS-D30 30 25 34 28 D226B-3D 30 ≈208 3 2200*1000*1250 940
GF/GFS-D40 40 32 44 35 TD226B-3D 45 ≈208 3 2300*1000*1350 1000
GF/GFS-D50 50 40 55 44 TD226B-3D 45 ≈208 4 2300*1000*1350 1000
GF/GFS-D63 63 50 69 55 TD226B-4D 60 ≈208 4 2350*1050*1400 1100
GF/GFS-D80 80 64 88 70 TD226B-6D 90 ≈208 6 2800*1150*1600 1400
GF/GFS-D100 100 80 110 88 TD226B-6D 90 ≈208 6 2800*1150*1600 1450
GF/GFS-D125 125 100 138 110 TBD226B-6D 120 ≈205 6 3000*1250*1650 1550
GF/GFS-D150 150 120 165 132 TBD226B-6D5 134 ≈205 6 3000*1250*1650 1600



60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator





60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator






60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator







60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 Welcome your further contact and sending inquiry!





















 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator pictures & photos
60Hz 440V/254V 3 Phase Geneator Set Electric Generators Silent Deutz Power 160 kVA Generator
US $10,400-12,400 / set
Min. Order: 1 set
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14000
Terms of Payment
LC, T/T