| Customization: | Available |
|---|---|
| After-sales Service: | 1 Year/1000 Hours |
| Warranty: | 1 Year/1000 Hours |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specification:
GF/GFS-C Series Diesel Generator with Cummins Egnine
50Hz Generator with Cummins Power |
|||||||||||
| Generator Set Performance | Engine Specification | Open Genset | Soundproof type | ||||||||
| Genset Model | 50Hz Output | Engine Model | Power(Kw) | Fuel Comsuption(100% Load) | Dimension | Weight | Dimension | Weight | |||
| 50Hz | Prime | Standby | KW | L/H | L*W*H (mm) | KG | L*W*H(mm) | KG | |||
| KVA | KW | KVA | KW | ||||||||
| G/GS-C250 | 250 | 200 | 275 | 220 | NT855-GA | 231 | 42.7 | 3000*1100*1800 | 2500 | 3500*1300*2000 | 3300 |
| G/GS-C250 | 250 | 200 | 275 | 220 | NTA855-G1 | 240 | 48.9 | 3000*1100*1800 | 2700 | 3500*1300*2000 | 3500 |
| G/GS-C275 | 275 | 220 | 312.5 | 250 | NTA855-G1A | 261 | 60.44 | 3000*1100*1800 | 2700 | 3500*1300*2000 | 3500 |
| G/GS-C313 | 313 | 250 | 344 | 275 | NTA855-G1B | 284 | 61.18 | 3000*1100*1800 | 2700 | 3500*1300*2000 | 3500 |
| G/GS-C344 | 344 | 275 | 375 | 300 | NTA855-G2A | 313 | 64 | 3000*1100*1800 | 3000 | 3500*1300*2000 | 3700 |
| G/GS-C350 | 350 | 280 | 387.5 | 310 | NTA855-G4 | 318 | 65 | 3000*1100*1800 | 3050 | 3500*1300*2000 | 3900 |
| G/GS-C375 | 375 | 300 | 412.5 | 330 | NTAA855-G7 | 343 | 69.9 | 3000*1100*1800 | 3100 | 3500*1300*2000 | 3900 |
| G/GS-C409 | 450 | 360 | NTAA855-G7A | 377 | 76.89 | 3000*1100*1800 | 3300 | 3500*1300*2000 | 4150 | ||
| G/GS-C450 | 450 | 360 | 500 | 400 | KTA19-G3 | 403 | 83.9 | 3450*1300*1800 | 4000 | 3800*1400*2100 | 5200 |
| G/GS-C500 | 500 | 400 | 550 | 440 | KTA19-G3A | 448 | 90 | 3450*1300*2000 | 4200 | 4200*1400*2200 | 5400 |
| G/GS-C500 | 500 | 400 | 550 | 440 | KTA19-G4 | 448 | 93.2 | 3850*1300*2000 | 4300 | 4200*1400*2200 | 5500 |
| G/GS-C525 | 525 | 420 | 631.2 | 505 | KTAA19-G5 | 470 | 97.9 | 3850*1300*2000 | 4600 | 4500*1400*2200 | 5900 |
| G/GS-C575 | 575 | 460 | 650 | 520 | KTAAA19-G6 | 520 | 107.2 | 3850*1300*2000 | 4600 | 4500*1400*2200 | 5900 |
| G/GS-C625 | 687.5 | 550 | KTAA19-G6A | 560 | 116.5 | 3850*1300*2000 | 4600 | 4500*1400*2200 | 5900 | ||
| G/GS-C625 | 687.5 | 550 | KTAA19-G7 | 560 | 116.5 | 3850*1300*2000 | 4600 | 4500*1400*2200 | 5900 | ||
| G/GS-C590 | 650 | 520 | KTA19-G8 | 575 | 116.5 | 3850*1300*2000 | 4600 | 4500*1400*2200 | 5900 | ||
| G/GS-C614 | 675 | 540 | KTA38-GA | 560 | 130 | 4500*1800*2450 | 6950 | 5500*2000*2900 | 8000 | ||
| G/GS-C625 | 625 | 500 | 687.5 | 550 | KTA38-G | 560 | 116.5 | 4500*1800*2450 | 6950 | 5500*2000*2900 | 8000 |
| G/GS-C750 | 750 | 600 | 825 | 660 | KTA38-G2 | 664 | 139.8 | 4500*1800*2450 | 7050 | 5500*2000*2900 | 8200 |
| G/GS-C800 | 800 | 640 | 887.5 | 710 | KTA38-G2B | 711 | 170 | 4500*1800*2450 | 7200 | 5500*2000*2900 | 8500 |
| G/GS-C910 | 910 | 728 | 1001 | 800 | KTA38-G2A | 813 | 170 | 4500*1800*2450 | 7200 | 5500*2000*2900 | 8500 |
| G/GS-C1000 | 1000 | 800 | 1100 | 880 | KTA38-G5 | 880 | 186.4 | 4800*1950*2400 | 7900 | 5800*2140*3080 | 9500 |
| G/GS-C1136 | 1250 | 1000 | KTA38-G9 | 1000 | 196 | 5800*2010*2500 | 8500 | 6800*2250*3080 | 10500 | ||
| G/GS-C1200 | 1200 | 960 | 1320 | 1056 | QSK38-G5 | 1063 | 220 | 5800*2010*2500 | 9000 | 6800*2250*3080 | 11000 |
| G/GS-C1250 | 1250 | 1000 | 1375 | 1100 | KTA38-G3 | 1097 | 233 | 5800*2010*2500 | 9000 | 6800*2250*3080 | 11000 |
| G/GS-C1375 | 1375 | 1100 | 1513 | 1210 | KTA50-G8 | 1200 | 256.3 | 5800*2010*2500 | 9000 | 6800*2250*3080 | 11000 |
| G/GS-C1450 | 1450 | 1160 | 1625 | 1300 | KTA50-GS8 | 1287 | 273 | 5800*2010*2500 | 9000 | 6800*2250*3080 | 11000 |






Fuzhou Genspark Equipment Co.,Ltd, is a diesel generator set manufacturer and supplier. Our main products are Cummins,Duetz,Perkins,Kubota,MTU,Weichai,SDEC and YandDong powered diesel generators, ranging from 10KW -2500KW. The model types could be Open type,Silent type,trailer type,container type, also could be customized types,like diesel generators in Parallel type,double voltage type and ect.
Our Factory has 2 hardware workshops,3 assembling and production lines,1 testing workshop and 1 package and delivery workshop, with more than 130 experience workers and more than 12 professional engineers and technician exports. Based on these qualification, we could produce high-quality products in mass, also could design out and manufacture customized generator sets.
Our products are exported to Middle East, America, Africa Areas and got positive feedback and acceptance from customers abroad. 







-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
| Helpful tips on Generator Set Fault | |||
| When fault occurs during generator set running,could do primary judgement according to following tips. | |||
| Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
| High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
| Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
| Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
| Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
| Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
| Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |
1. What's the nearest export seaport to you?
It is Fuzhou seaport .
2. What are your terms of payment?
T/T, LC will be acceptable.
3.How long is your delivery time?
Depending on the customers purchase diesel generators' configuration, customer demand for delivery, and our parts inventory, etc.
Generally,it takes 20-25 workday for open type diesel generators and 30-45 workdays for silent type diesel generator and container type.
4.What's your MOQ?
1 unit, if have more quantity, better price will be offered.
5.How much is the ocean freight?
It depends on the destination seaport.
6. How to pack the products?
For better protection of products, customers are advised to use FCL transport, try not to ship by LCL.
Poly-Film Package or Ply-wooden package.