• Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  • Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  • Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  • Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  • Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  • Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power

Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power

After-sales Service: 1 Year/1200 Hours
Warranty: 1 Year/1200 Hours
Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF/GFS-C200KW
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Engine Model
6ltaa8.9-G2
Alternator
Stamford/ Leroy Somer/Stamford Copy
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8-9 Hous Fuel Tank
Controller
Comap/Smartgen/Deepsea
Alternative
Installing with ATS
Color
Depends
Frequency
60Hz
Voltage
220V/127V 3 Phase
Engine
with Cummins Power
Transport Package
Wooden Package
Specification
10CBM
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power


Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power




 Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power

Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
  
 

Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power 60Hz Diesel Generator Set with Cummins Power
 
Generator Set Performance Engine Specification Soundproof type
Genset Model 60Hz Output Engine Model Power(Kw) Fuel Comsuption(100% Load) Dimension Weight
60Hz Prime  Standby KW L/H L*W*H(mm) KG
KVA KW KVA KW
G/GS-C27 27.5 22 32.5 26 4B3.9-G1/G2 27 6 1950*830*1100 1250
G/GS-C37 37 30 41 33 4BT3.9-G1/G2 40 8 2200*950*1200 1350
G/GS-C43 42.5 34 47 37 4BT3.9-G1/G2 40 8 2200*950*1200 1350
G/GS-C60 60 48 66 53 4BTA3.9-G2 60 9.8 2400*950*1360 1450
G/GS-C68 68 55 75 60 4BTA3.9-G2 60 13 2400*950*1360 1450
G/GS-C85 85 68 94 75 6BT5.9-G1/G2 92-102 23 2700*1100*1450 1800
G/GS-C100 100 80 110 88 6BT5.9-G1/G2 92-102 23 2700*1100*1450 1850
G/GS-C113 100 80 110 88 6BT5.9-G1/G2 92-102 23 2700*1100*1450 1900
G/GS-C125 125 100 137 110 6BTA5.9-G2 120 23 2700*1100*1450 2000
G/GS-C137 138 110 151 121 6BTA5.9-G2 120 23 2800*1150*1560 2100
G/GS-C150 150 120 165 132 6BTAA5.9-G2 132 26 2800*1150*1560 2150
G/GS-C180 180 144 198 158 6CTA8.3-G2 180 33.9 3100*1100*1510 2350
G/GS-C187 187 150 206 165 6CTA8.3-G2 180 35.1 3100*1100*1510 2400
G/GS-C225 225 180 248 198 6CTAA8.3-G2 201 38.7 3300*1150*1800 2550
G/GS-C250 250 200 275 220 6LTAA8.9-G2 240 38.7 3300*1150*1800 2700
G/GS-C275 275 220 303 243 6LTAA8.9-G2 240 38.7 3300*1150*1800 2750





Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power





Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power
Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power






Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power







Good Price Top Performance Silent Type 250kVA Diesel Generator Price with Cummins Power



-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 

Welcome your sending inquriy or contact directly!








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14000
Terms of Payment
LC, T/T