Technical Data of Genset | Diesel Engine | ||||||
Model(50Hz) | Rated Power | Rated Voltage(V) | Rated Frequency(Hz) | Engine Model | Cylinder NO. | Emmission | |
KW | KVA | ||||||
GF/GFS-YC37 | 30 | 37.5 | 220-480 | 50 | YC4D60-D21 | 4 | Euro 2 |
GF/GFS-YC50 | 40 | 50 | 220-480 | 50 | YC4D60-D21 | 4 | Euro 2 |
GF/GFS-YC100 | 80 | 100 | 220-480 | 50 | YC6B135Z-D20 | 6 | Euro 2 |
GF/GFS-YC180 | 145 | 181 | 220-480 | 50 | YC6A230L-D20 | 6 | Euro 2 |
GF/GFS-YC250 | 200 | 250 | 220-480 | 50 | YC6M350L-D20 | 6 | Euro 2 |
GF/GFS-YC315 | 250 | 315 | 220-480 | 50 | YC6MK420L-D20 | 6 | Euro 2 |
GF/GFS-YC438 | 350 | 437.5 | 220-480 | 50 | YC6T550L-D21 | 6 | Euro 2 |
GF/GFS-YC475 | 380 | 475 | 220-480 | 50 | YC6T600L-D20 | 6 | Euro 2 |
GF/GFS-YC500 | 400 | 500 | 220-480 | 50 | YC6T660L-D20 | 6 | Euro 2 |
GF/GFS-YC562 | 450 | 562 | 220-480 | 50 | YC6T700L-D20 | 6 | |
GF/GFS-YC625 | 500 | 625 | 220-480 | 50 | YC6T830L-D20 | 6 | |
GF/GFS-YC750 | 600 | 750 | 220-480 | 50 | YC6C1020L-D20 | 6 | Euro 2 |
GF/GFS-YC875 | 700 | 875 | 220-480 | 50 | YC6C1170L-D20 | 12 | |
GF/GFS-YC1000 | 800 | 1000 | 220-480 | 50 | YC6C1320L-D20 | 12 | |
GF/GFS-YC1500 | 1200 | 1500 | 220-480 | 50 | YC12C2040L-D20 | 12 |
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |